Three sentences first. The wall of every pull-down (attraction) system is P ∝ h2 — double the gap, quadruple the drive power. Breakthrough level one: let a permanent-magnet ring carry the static load, and power falls with (1−η)2 — moving the bias ratio η from 80% to 95% is a 16× reduction. Level two: split the correction work across a multi-matrix coil array, and total drive power falls as 1/N — double the channels, halve the power.

The wall: the square law of the gap

The full derivation chain, four steps:

F = B2·A / (2μ₀)

Maxwell stress (magnetic pressure): B = flux density at the pole face · A = pole area · μ₀ = permeability of free space

Bneed = √(2μ₀·mg / A)

Balance condition F = mg solved for B. Note what is not in this formula: the gap. Required B is set by payload and pole area alone

NI = B·h / μ₀

Air-gap ampere-turns: N = turns, I = current, h = gap length. Two gaps in series → double it

Pcu = ρ·(NI)2·ℓ / (kfill·Aw)

Copper loss: ρ = resistivity, ℓ = mean turn length, kfill = winding fill factor, Aw = winding window. Net result: Pcu ∝ (NI)2 ∝ h2

The key insight: the B you need has nothing to do with the gap — the entire price is paid in pushing that B across the air.

Gap h (mm)152025304050
Relative power (P ∝ h2)1.01.82.84.07.111.1
Engineering meaningNatural coolingAcceptableCooling must be consideredHeatsink + airflowThermal design becomes a main costImpractical at consumer grade

Level one: the magnet ring carries the static load (bias ratio)

Btotal = Bpm + Bcoil,  η = Bpm / Bneed  →  P / P₀ = (1 − η)2

Bpm = field contributed by the permanent magnet ring · Bcoil = field the coil must add · η = bias ratio · P₀ = power of a pure electromagnet doing the same job

Bias ratio η0 (pure EM)50%80%90%95%99%
Coil must supply100%50%20%10%5%1%
Relative power100%25%4%1%0.25%0.01%
100% 10% 1% 0.1% 0.01% 0 25% 50% 75% 100% Bias ratio η (permanent-magnet share of required field) Relative coil power (log scale) η 80% → 4% η 95% → 0.25%

P/P₀ = (1−η)2 on a log scale: the leverage is in the last few points of bias.

The leverage point: moving η from 80% to 95% shifts only 15 more points of load onto the magnet — and cuts coil power sixteen-fold.

Bonus: linearity comes along

F = (Bpm + ΔB)2·A/(2μ₀) = Bpm2A/(2μ₀) + (Bpm·ΔB·A/μ₀) + ΔB2A/(2μ₀)

Three terms: static lift (free) · controllable force proportional to coil current, with gain amplified by Bpm · a small quadratic remainder

While ΔB ≪ Bpm, the controllable force is linear in current — and its gain is amplified by Bpm. A pure electromagnet is a square-law, single-polarity, asymmetric actuator; add bias and it becomes a linear, bidirectional one.

Level two: multi-matrix coils

Fix the total correction force Fc and split it across N channels: current per channel scales as 1/N, copper loss per channel as (1/N)2, and N channels together:

Ptotal = N × (1/N)2 × P₁ = P₁ / N

P₁ = power of a single channel doing all the correction work — double the channels, halve the total power

Channels N124 (common today)812
Current per channel1.000.500.250.1250.083
Total power1.0000.5000.2500.1250.083

Two extra dividends:

The costs, honestly:

How float distance goes up

After two stages of power saving, height stops being a power problem and becomes a geometry problem again.

A = π·(Ro2 − Ri2)

A = pole area · Ro = outer radius · Ri = inner (bore) radius — the pivot of the height-versus-load trade-off

A ring magnet’s field lines leave the outer edge, arch over the top, and return to the inner edge — how high they can arch sets the usable height. A larger bore arches higher, but shrinks the pole area.

OrientationBorePole area AUsable heightLoad capacity
CompactSmallLargeLowerHigh
BalancedMediumMediumMediumMedium
High-floatLargeSmallHighMust be bought back with outer diameter

Public material reference: hard ferrite remanence ≈ 0.4 T; sintered NdFeB N42 ≈ 1.3 T — roughly three times. At equal pole area there is real headroom in both height and load; the price is material cost and thermal management.

Conclusion: height can only be bought with area and magnet grade — high float is naturally a premium tier.

The cost ledger

ItemChangeNote
Magnet ring↑Larger volume, higher grade
Coils & drivers↑Channel count N grows
Power adapter↓↓Power falls with (1−η)2·(1/N) — the adapter spec drops sharply
Thermal structure↓↓Less heat → simpler heatsinks, airflow paths and vents
Long-term reliability↑Lower temperature rise → longer life and steadier performance

Conclusion: BOM goes up, but the system-level total cost can tie — or even win. For certified, always-on display products it is especially worthwhile.

Formula cheat sheet

RelationExpressionUse
Magnetic pressureF = B2A/(2μ₀)Load capacity
Required flux densityBneed = √(2μ₀mg/A)Design starting point — independent of the gap
Air-gap ampere-turnsNI = B·h/μ₀Turns and current
Copper lossPcu ∝ (NI)2→ yields P ∝ h2
Bias benefitP/P₀ = (1−η)2Direct conversion of the magnet’s share
Array benefitP ∝ 1/NDouble the channels, halve the power
Pole areaA = π(Ro2−Ri2)Pivot of the height-load trade-off

The honesty clause

In a pull-down system the vertical axis is actively stabilized. Per Earnshaw’s theorem, a static magnetic field cannot be passively stable in all degrees of freedom at once, so the control loop must stay powered. Magnetic bias can press static power extremely low — but never to true zero. The architecture that genuinely approaches zero static power is the push-up (repulsion) system.